To perform a basic distance measurement with the Hilti PD 32, press the "Measure" key once to switch on the range meter and activate the laser beam. Aim the visible laser spot at a target about 3 to 10 meters (10-30 ft) away. Press the "Measure" key again, and the distance will be shown in less than 1 second.

Was this helpful? What should I do if the Hilti PD 32 displays a general hardware error?

If your Hilti PD 32 displays a general hardware error, you should switch the range meter Off and then back On. If the error persists, you should notify your local Hilti service centre. For more information, see page 17 of the manual.

Was this helpful? How accurate is the Hilti PD 32 laser range meter?

The Hilti PD 32 laser range meter typically has an accuracy of ±1.5 mm (±1/16 inch) for individual and continuous measurements. This accuracy can be affected by atmospheric conditions, especially at distances greater than 100 m (300 ft), with an effect of ± (1.5 mm + 20 ppm) / + (1/16 inch + 20 ppm).

Was this helpful? Where can I get my Hilti PD 32 laser range meter repaired?

You should have your Hilti PD 32 laser range meter repaired only at a Hilti service center. Unauthorized opening of the range meter may cause the emission of laser radiation in excess of class 2. If the range meter is found to be damaged, have it repaired at a Hilti service centre.

Was this helpful? What is the maximum measuring range of the Hilti PD 32 laser range meter?

The Hilti PD 32 laser range meter has a measuring range of 0.05 m to 200 m (2 inch to 600 ft) from the front edge. The maximum distance resolution is 750 m (2,500 ft). The maximum range depends on the reflectivity of the target surface and ambient light conditions. For more information, see page 10 of the manual.

Was this helpful? How do I replace the batteries in my Hilti PD 32 laser range meter?

To replace the batteries in your Hilti PD 32, first lightly press the lid of the battery compartment. Then, slide the lid out and off, and proceed to replace the batteries. Ensure you observe the correct polarity and that the battery compartment is properly locked after replacement. For alkaline batteries, always replace a complete set and do not mix used and new batteries or different makes/types. Only use undamaged, approved batteries. For rechargeable batteries, always use those of the same make and type. For more information, see page 13 of the manual.

Was this helpful? How do I turn the Hilti PD 32 laser range meter on and off?

The Hilti PD 32 laser range meter is switched on or off by pressing the "On / Off" key. For more information, see page 14 of the manual.

Was this helpful? What type of batteries does the Hilti PD 32 laser range meter use?

The Hilti PD 32 uses two standard alkaline primary cells of type AA (LR6, AM3, Mignon). Alternatively, it can use rechargeable NiMH cells. For more information, see page 10 of the manual.

Was this helpful? How do I charge the rechargeable batteries for the Hilti PD 32?

To charge the rechargeable batteries for your Hilti PD 32, first attach the PDAW 80/81-1 charging adaptor into the range meter. For charging, connect either the mains adapter or the car battery plug to the charging adaptor. The maximum charging time for empty cells is approximately 12 hours, though sufficient current for 150-200 measurements is charged within the first 15 minutes. The charging process can be interrupted at any time without damaging the battery cells. For more information, see pages 8, 9 and 13 of the manual.

Was this helpful? Why might the Hilti PD 32 show unfavourable signal conditions during measurement?

The Hilti PD 32 might show unfavourable signal conditions due to insufficient reflected laser light. To address this, ensure the measuring distance is greater than 50 mm (2 inch) from the front edge, clean the lens, or take a measurement from another surface or use the target plate PDA 50. For more information, see page 17 of the manual.

Was this helpful? How long does the battery last in the Hilti PD 32 laser range meter?

At 25°C (77°F), the Hilti PD 32 can perform approximately 15,000 - 20,000 measurements with a single set of alkaline batteries, and 8,000 - 10,000 measurements with NiMH rechargeable batteries. For more information, see page 10 of the manual.

Was this helpful? How do I measure from corners using the Hilti PD 32 laser range meter?

To measure from corners with the Hilti PD 32, first fold out the spike 90°. This automatically sets the measuring reference to the end of the spike, and the range meter corrects measured distances accordingly. Position the range meter with the spike at your desired starting point and aim towards the target, then press the "Measure" key.

Was this helpful? How can I tell if the Hilti PD 32's rechargeable battery is fully charged?

The level of charging for the Hilti PD 32 is indicated by the movement of battery display segments at the top right of the display. When the battery is fully charged, "Accu Full" will be displayed. For more information, see page 13 of the manual.

Was this helpful? How do I reset a calculation function on the Hilti PD 32 if I made a mistake?

If a measurement using a calculation function has been carried out incorrectly or unintentionally on the Hilti PD 32, you can reset the function at any time by pressing the same function key again or any other function key. For more information, see page 16 of the manual.

Was this helpful? Can the Hilti PD 32 measure distances through transparent surfaces like glass?

It is generally not possible for the Hilti PD 32 to measure distances to transparent materials like liquids, foam polystyrene, or glass, as light penetrates these materials, which can lead to measuring errors. For more information, see page 22 of the manual.

Was this helpful? What is fast battery charging for the Hilti PD 32 and how does it work?

Fast battery charging for the Hilti PD 32 ensures that within 15 minutes of charging with the PDAW 80/81-2 car battery plug, the battery receives enough power for an additional 150 to 200 measurements. This is particularly useful when you need the range meter ready for use quickly.

Was this helpful? What should I do if the Hilti PD 32 is used in very bright surroundings?

If the Hilti PD 32 is used in very bright surroundings, the laser spot may not be visible. The built-in optical target sight helps aim the laser. For long distances and bright light conditions, it is recommended to use the PDA 50 target plate. You can also shade the target from bright light or use the target plate PDA 50 if the ambient light at the target is too bright. For more information, see pages 17 and 21 of the manual.

Was this helpful? How do I activate the setting menu on the Hilti PD 32?

To activate the setting menu on the Hilti PD 32, press the "On / Off" key for about 2 seconds while the range meter is switched off. From this menu, you can set the beep and the units. For more information, see page 15 of the manual.

Was this helpful? What happens if I insert alkaline batteries into the Hilti PD 32 when it expects rechargeable ones?

If alkaline batteries are unintentionally inserted into the Hilti PD 32, all battery status segments will flash continually, indicating missing rechargeable batteries. Additionally, "Accu no" will be shown in the display. The range meter cannot be switched on in this state. For more information, see page 14 of the manual.

Was this helpful? How should I clean my Hilti PD 32 laser range meter?

To clean your Hilti PD 32, first blow dust off the lens. Do not touch the lens with your fingers. Use only a clean, soft cloth for cleaning, and if necessary, slightly moisten the cloth with pure alcohol or a little water. Do not use any other liquids as they might damage the plastic parts. For more information, see page 30 of the manual.

Was this helpful? How does the Hilti PD 32 handle measurements on rough surfaces?

When measuring to rough surfaces like coarse render or stucco with the Hilti PD 32, it measures an average distance value. The center of the laser spot is weighted higher than the edges of the laser spot for this measurement. For more information, see page 21 of the manual.

Was this helpful?

Need help?

Do you have a question about the PD 32 and is the answer not in the manual?

Ask a question Questions and answers Steven Stepnowski April 28, 2025

can you get the pd32 repaired

Same question (0) Add my comment 1 comments: Mr. Anderson May 15, 2025

Yes, the Hilti PD 32 can be repaired as long as it is operated and handled correctly, cleaned and serviced properly, and only original Hilti consumables, components, and spare parts are used.

This answer is automatically generated

March 21, 2025

How do I make my hilti pd32 open

Zoom image Same question (0) Add my comment Related Manuals for Hilti PD 32 Laser range meter (30 pages) Sitemaster building ce/pocket pc (4 pages) Laser range meter (79 pages) Laser range meter (148 pages) Summary of Contents for Hilti PD 32
  • Page 1 PD 32 Operating instructions 1–30 Mode d’emploi 31–60 Istruzioni d’uso 61–90 Manual de instruções 91–120 Manual de instrucciones 121–150 Printed: 07.07.2013 | Doc-Nr: PUB / 5070013 / 000 / 00.
  • Page 2 Printed: 07.07.2013 | Doc-Nr: PUB / 5070013 / 000 / 00.
  • Page 3 PDA 50 PDA 80 PDA 60 PDA 81 PDA 61 PDAW 80-1 PDA 62 PDAW 80 / 81-1 PDA 70 PDAW 80 / 81-2 PUA 60 PDAW 80 / 81-3 PDAW 81-1 Printed: 07.07.2013 | Doc-Nr: PUB / 5070013 / 000 / 00.
📎📎📎📎📎📎📎📎📎📎